Global
Language
IP66
50dB
GoodWe ET G3 Series is a next-generation three-phase hybrid inverter designed for commercial and industrial energy storage applications. Combining high-performance energy conversion, flexible system scalability, and reliable backup capability, it enables efficient solar utilization and supports diverse energy scenarios. With advanced system integration and microgrid readiness, ET G3 provides a future-ready energy solution for businesses seeking greater energy independence and operational flexibility.
Up to 200% DC input oversizing
2 × 100A Dual Battery Inputs
Generator Peak Shaving
Starts More, Motor-Friendly
IP66
50dB
Smart energy starts with capturing every ray. Five independent MPPT trackers handle complex rooftop layouts and mixed orientations, while up to 200% PV oversizing lets you install more panels than rated — turning early mornings, late afternoons, and shaded strings into real kilowatt-hours. With dual 100A battery inputs, you're free to expand storage gradually, mixing existing and new battery banks rather than replacing everything at once.
5 MPPTs: More flexible sloar panel layouts
200% PV Oversizing: Make the most of your roof
2×100A Dual Battery Inputs: Mix, Match & Expand with Ease
Backup that doesn't blink. 0 ms seamless on-grid/off-grid switching keeps critical loads online the instant the grid drops, while the motor-friendly design confidently starts pumps, compressors, and other high-inrush equipment without tripping. Generator peak shaving automatically trims demand spikes and fuel consumption.
0 ms Seamless Switching (under grid open-circuit conditions): UPS-Level Backup, Zero Break
Motor-Friendly Inrush Handling: Starts More, Powers Everything
Generator Peak Shaving: Run smarter. Burn less fuel
Model
GW30K-ET-L-G30
Battery Voltage Range (V)
150 ~ 650
Max. Continuous Charging / Discharging Current (A)
100 / 100
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
30
Back-up Nominal Apparent Power (kVA)
30
Model
GW25K-ET-L-G30
Battery Voltage Range (V)
150 ~ 650
Max. Continuous Charging / Discharging Current (A)
100 / 100
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
25
Back-up Nominal Apparent Power (kVA)
25
Model
GW18K-ET-L-G30
Battery Voltage Range (V)
150 ~ 650
Max. Continuous Charging / Discharging Current (A)
80 / 80
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
18
Back-up Nominal Apparent Power (kVA)
18
Model
GW50K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
100 / 100
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
50
Back-up Nominal Apparent Power (kVA)
50
Model
GW49.999K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
100 / 100
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
49.999
Back-up Nominal Apparent Power (kVA)
49.999
Model
GW40K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
100 / 100
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
40
Back-up Nominal Apparent Power (kVA)
40
Model
GW37.5K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
100 / 100
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
37.5
Back-up Nominal Apparent Power (kVA)
37.5
Model
GW30K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
80 / 80
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
30
Back-up Nominal Apparent Power (kVA)
30
Model
GW29.999K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
80 / 80
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
29.999
Back-up Nominal Apparent Power (kVA)
29.999
Model
GW25K-ET-G30
Battery Voltage Range (V)
150 ~ 950
Max. Continuous Charging / Discharging Current (A)
80 / 80
Max. Input Current per MPPT (A)
42
Max. Apparent Power Output to Utility Grid (kVA)
25
Back-up Nominal Apparent Power (kVA)
25